Product Introduction

The thermoelectric generator is composed of high-strength bismuth telluride thermoelectric material, high thermal conductivity and high insulation DBC (direct bonding copper) ceramics and high-temperature solder, which is suitable for use in the environment where the hot end is 200 degrees.


characteristic

High performance, can work under 200 ℃ temperature difference for a long time
High reliability, ordinary service life more than 10 years
High temperature resistance, hot surface can be used at 200 ℃
Conform to RoSH requirements
Provide customized services


application area

Fireplace fan
Field barbecue
Power supply for low-power electronic equipment
Fire control system
Control system


Relevant definitions

name Symbol Company
Seebeck coefficient α Volts/K
Hot surface temperature Th K
Cold surface temperature Tc K
Temperature difference ΔТ= Th-Tc K
Device resistance Ri Ohms
Load resistance RL Ohms
Open circuit voltage U open circuit Volts
Open circuit current I open circuit A
Maximum output power Pmax Watts

Theoretical basis of thermoelectric power generation

According to Seebeck effect, open circuit (no load) voltage U=a (Th Tc)=a* ΔТ-- Formula ①
Considering load, output voltage=a* ΔТ* RL/(Ri+RL) --------------- Formula ②
Current in the circuit I=U/(Ri+RL)=a* ΔТ/ (Ri+RL) --------------- Formula ③
When no load RL=0, it is called an open circuit, and the open circuit current I=a* ΔТ/ Ri -------- type ④
From P=UI, output power=a* ΔТ* RL/(Ri+RL) *a* ΔТ/ (Ri+RL)
That is, P=a 2* ΔТ 2 * RL/(Ri+RL) 2 ------------ Formula ⑤
When Ri=RL, P=Pmax=a 2* ΔТ 2/(4Ri) -------------------- Type ⑥
According to formulas ⑤ and ⑥, the output power is proportional to the square of the temperature difference.
The maximum output power is inversely proportional to the internal resistance of the device.
According to formula ②, the larger the load resistance is, the greater the output voltage will be.


 Application Considerations

Application Considerations

● The generator module must be installed on a flat surface, and the flatness of the contact surface is required to be more than 30 microns.
● It is suitable for long-term operation under the condition that the hot end temperature is 0~200 ℃.
● Please obtain the maximum operating temperature from customer service.


Model of thermoelectric generator

Cold surface temperature=50 ℃; Hot surface temperature=200 ℃; Data with temperature difference of 150 ℃

model Nickname Ri (Ω) at different temperatures Open circuit voltage Open circuit current maximum power Dimension mm ³ Specification download
Length L Width W Thickness H
30℃ 150℃ Ri=RL(V) (A) (W) (mm) (mm) (mm)
one hundred and twenty-seven thousand three hundred and sixty-five HT064365 three point six zero four point zero eight six point eight zero zero point seven five one point two seven twenty-five twenty-five three point four five PDF
one hundred and twenty-seven thousand three hundred and sixty-five --- three point six zero four point zero eight seven point zero five zero point seven seven one point three seven thirty thirty three point four five PDF
one hundred and twenty-seven thousand three hundred and sixty-five --- three point six zero four point zero eight seven point one seven zero point seven eight one point four zero forty forty three point nine PDF
one hundred and twenty-seven thousand two hundred and twenty --- two point two zero two point six eight seven point zero eight one point two seven two point two five forty forty three point seven PDF
one hundred and twenty-seven thousand and two hundred --- two two point four eight six point nine five one point four three two point four eight forty forty three point nine PDF
one hundred and twenty-seven thousand one hundred and forty-one HT064141 one point four zero one point eight eight six point five six one point six seven two point seven three forty forty three point five five PDF
one hundred and twenty-seven thousand one hundred and twelve HT064112 one point one one one point five nine six point three zero two point zero five three point two three forty forty three point two five PDF
one hundred and ninety-nine thousand three hundred and forty-five --- three point four five three point nine three ten point four one one point two three point one two forty forty three point seven PDF
two hundred and forty-one thousand one hundred and sixty-four HT121164 one point six five one point nine one ten point nine six two point one two five point eight one fifty-five fifty-five three point zero five PDF
 Geometric dimension

Sealing glue type

Code Type of sealant colour describe
NS Unsealed adhesive
White silicon rubber white No corrosion, meeting Rohs requirements
Red silicon rubber gules No corrosion, meeting Rohs requirements
CS Meet customer customization requirements

other

Optional graphite film available