91香蕉视频ioS下载入口

Current position: thermoelectric knowledge ->four main performance indicators of semiconductor refrigeration chips

Four main performance indexes of semiconductor refrigeration chips

Refrigerating plate, performance

The four main performance parameters of semiconductor cooler refer to:

Maximum current Imax: refers to the constant hot surface temperature Th, when the load Qc is 0 Δ T reaches Δ The current value at Tmax is the maximum current value.

Maximum current Umax: refers to the constant hot surface temperature Th, when the load Qc is 0 Δ T reaches Δ The voltage value at Tmax is the maximum voltage value.

Maximum temperature difference Δ Tmax: when the heat absorption of the cold surface is 0, the temperature of the hot surface is constant. When I=Imax, the maximum temperature difference between the cold surface and the hot surface can be reached.

Maximum heat absorption QCmax: constant hot surface temperature, temperature difference between cold surface and hot surface Δ When T=0, the heat that can be absorbed by the cooling surface when I=Imax.